Addition-cure silicone is a two-component, high-performance organosilicon material with platinum as a catalyst. It cures without byproducts and has extremely low shrinkage, making it widely used in precision mold making, electronic potting, food-grade products, and medical aids. In practice, it's common to encounter sticky surfaces and areas that don't fully dry after curing. This is usually not a material quality issue, but rather a result of oversights in the operational details. Taking these precautions can significantly reduce the number of problems.
I. Catalyst Poisoning
The curing of addition-cure silicone relies on a platinum catalyst. It is chemically extremely sensitive. Once it comes into contact with compounds containing nitrogen (N), phosphorus (P), sulfur (S), or heavy metals (such as tin Sn and lead Pb), its active centers will be occupied or destroyed, leading to the interruption of the catalytic chain reaction.
Common sources of contamination include: condensation-type silicone residue, natural rubber, some resins, epoxy curing agents, oil sludge, skincare products on the hands, and environmental fumes.
Prevention methods: Use dedicated tools for specific purposes and never mix them with tools for condensation-type silicone; thoroughly clean the substrate surface before operation; conduct small-scale compatibility tests on unknown substrates first; keep the operating environment dry and well-ventilated, and avoid smoking.
II. Imbalance in A/B Component Ratio and Uneven Mixing
Two-component addition-cure silicone rubber has strict mixing ratio requirements for components A and B (commonly 1:1 or 10:1). If the ratio deviates significantly or mixing is uneven, the proportion of reactive groups will be unbalanced, preventing complete cross-linking and resulting in incomplete curing or stickiness.
Solution: Use an electronic scale to mix by weight, not by feel or volume estimation. Stir clockwise to ensure complete mixing of the rubber on the walls and bottom of the container. For batch applications, use professional metering and mixing equipment to ensure proper ratio and uniformity of mixing.
III. Improper Storage or Expiration of Raw Materials
Improper storage of platinum catalysts and hydrogen-containing components—such as prolonged exposure to open containers, high temperatures or strong light, or exceeding the shelf life—may lead to catalyst deactivation or reduced activity.
Solution: Store in a sealed container at the specified temperature, away from light and heat; use within the shelf life; after opening, completely seal to prevent air, moisture, and impurities from entering.
Addition-cure silicone has high requirements for environment and operation. Controlling the tools, proportions, mixing, and storage are key points to effectively prevent stickiness and failure to dry. If you encounter silicone curing problems during production and need technical support or product selection assistance, please leave a message to consult HANAST Silicone for a one-on-one solution.