After silicone gel encapsulation, it was found that some parts were not cured. What could be the possible reason?

2025-09-11

The main causes may be:

Uneven mixing: Components A and B are not fully mixed.

Proportion error: The mixing ratio is inaccurate.

Catalyst poisoning: Contact with substances containing sulfur, phosphorus, amines, etc. (such as certain rubbers, flux residue, and epoxy resin).

Local temperature is too low.