HN100 is a single-component, non-curing thermally conductive silicone grease that combines 1.0 ± 0.1 W/m·K thermal conductivity (ASTM D5470) with 2450 V/mm dielectric strength at 0.20 mm (IEC 60243). It is a white or grey paste with a specific gravity of 1.85 ± 0.08 g/cm³ and a penetration of 370 ± 20 (1/10 mm), which keeps it soft, easy to dispense and easy to spread at the thin films that power supply interfaces need.
The grade is built for the place where thermal and electrical requirements meet: the interface between a live component and a grounded heat sink, housing or heat strip, in switching power supplies, transformers, inductors, thermostats, PTC heaters and heating elements. It holds paste consistency from −50 °C to +200 °C, does not powder after 8 days of continuous 200 °C baking, and does not dry out after 3 hours on a 280 °C heating platform.
Dielectric strength is quoted as a field strength, not as a guaranteed withstand voltage of a random film. For HN100 the TDS value is measured on a 0.20 mm film, so the reference withstand of a film scales with thickness as shown below. Use it as a design check, not as a substitute for the isolation barrier.
| Grease film thickness | Reference withstand (2450 V/mm, linear estimate) | Practical reading |
|---|---|---|
| 0.05 mm | approx. 120 V | Thermal interface only, no electrical function |
| 0.10 mm | approx. 245 V | Low voltage secondary side, extra margin on creepage path |
| 0.20 mm | approx. 490 V | TDS test thickness, still far below a primary to secondary HIPOT level |
So the honest conclusion: HN100 is an insulating thermal grease, not an insulation barrier. For a 400 V DC bus power supply, or for a 1.5 kV AC routine HIPOT between primary and secondary, the isolation must come from the housing wall, the insulating tape, the slot liner or the potting layer. HN100 supports that design by keeping the interface electrically clean, by preventing a conductive thermal path, and by staying non-corrosive and non-toxic on terminals and enamel wire surfaces.
Most grease failures in a power supply are not conductivity failures, they are drying and powdering failures: the oil phase leaves, the filler hardens and the interface opens up at the hot spot. HN100 is specified for both of those conditions.
| Hot component | Why the stability data matters |
|---|---|
| PTC heater and heating element | Continuous surface temperature close to or above 200 °C. HN100 shows no powdering after 8 days in a 200 °C oven and no drying after 3 hours on a 280 °C plate, so the paste does not turn into a hard crust. |
| Thermostat, bimetal thermal switch and thermal fuse area | Slow thermal response and drift come from a dried interface. A paste that stays soft keeps the switching point repeatable batch after batch. |
| Transformer and inductor coil surface | Enamel wire and lamination stacks are hot and often vibrating. Low oil separation of 0.3 percent or less keeps the winding surface free of oil film and dust build-up. |
| Rectifier bridge, thyristor and triac on a grounded heat sink | An insulating interface is needed between the live tab and the heat sink, so dielectric strength and thermal path have to be handled together. |
| Terminal, connector and busbar interfaces | Non-corrosive and non-toxic, with low volatility of 0.6 percent or less, so contacts stay clean over service life. |
| Property | Test method / condition | Unit | Value |
|---|---|---|---|
| Appearance | Visual inspection | – | White or grey paste |
| Thermal conductivity | ASTM D5470 | W/m·K | 1.0 ± 0.1 |
| Specific gravity | GB/T 13354-1992 / 25 °C | g/cm³ | 1.85 ± 0.08 |
| Oil separation (oil bleed) | SH/T 0324-1992 / 200 °C, 24 h | % | ≤ 0.3 |
| Volatile matter | SH/T 0337-92 / 200 °C, 24 h | % | ≤ 0.6 |
| Penetration (cone penetration) | GB/T 269-2023 / 25 °C | 1/10 mm | 370 ± 20 |
| High temperature stability | 200 °C constant temperature oven, 0.2 mm film | – | No powdering after 8 days continuous baking |
| Temperature resistance | Heating platform 280 °C, 0.2 mm film | – | No drying after 3 hours continuous baking |
| Breakdown voltage | IEC 60243 / 0.20 mm thickness | V/mm | 2450 |
| Operating temperature range | – | °C | −50 to +200 |
| Compliance | RoHS 2.0, non-toxic, odourless, non-corrosive | – | Compliant |
Values are measured under standard conditions and are for reference only. Real thermal and electrical performance depends on bond line thickness, surface roughness, flatness and contact pressure, so verify the interface on your own hardware before drawing release.
Applications: 25 interface points across power supplies, heating products and appliancesThese are the application points our Southeast Asia customers write into drawings, process sheets and bills of material for this grade.
Power conversion and supply![]()
For the factory owner and plant manager
One insulating paste covers the power supply line, the heating product line and the after sales rework bench, so you carry less stock and train operators once. Because it never cures there is no oven, no cure fixture and no waiting time before the next process, and a mis-assembled unit can be wiped and re-applied instead of scrapped.
For the purchasing and procurement team
MOQ is 1 kg and standard packs are 1 kg and 5 kg plastic drums, with custom pack sizes on request. Capacity is 50 tons per month and lead time is typically 7 to 15 days. Every delivery ships with a technical data sheet and a safety data sheet, batch certificates of analysis are available on request, and the product is classified as non-dangerous goods, so sea and air freight to Vietnam, Thailand, Indonesia, Malaysia and the Philippines need no dangerous goods declaration. A second source is not required because the sample, pilot and production drums use the same formulation.
For the electrical and process engineer
Apply by brush, roller, automatic dispensing or screen printing after solvent cleaning and drying. Dispense a pattern that covers 60 to 80 percent of the contact area, assemble immediately and torque to the heat sink supplier specification. Penetration 370 ± 20 keeps the paste spreadable at thin film, and because it stays paste it does not build up a cured skin that changes the interface after the first thermal cycle. Keep the paste off any dimension that a safety standard measures as creepage or clearance.
For the quality and reliability engineer
The two numbers that predict field behaviour are oil separation up to 0.3 percent and volatile matter up to 0.6 percent at 200 °C for 24 hours, plus the 8 day 200 °C no-powdering and 3 hour 280 °C no-drying stability results. Add breakdown voltage at 0.20 mm and penetration at 25 °C to the incoming inspection sheet, and compare each batch certificate of analysis against the approved sample. Run your own damp heat and thermal cycling on the finished assembly before design freeze.
For the project and product manager
The HN family is a graded platform so a product line can be positioned without changing supplier: 1.0 W/mK HN100 for insulating power supply and heating interfaces, 2.0 W/mK for general electronics, 2.95 W/mK for clamped power modules, 4.0 W/mK for charger and SiC module interfaces, and 5.0 to 6.0 W/mK metal-filled grades for CPU and GPU cooling. Sampling is a 1 kg drum and the formulation is identical from sample to mass production, so a validation done on the sample stays valid after ramp up.
| Grade | Conductivity | Dielectric strength | Best fit |
|---|---|---|---|
| HN100 | 1.0 W/m·K | 2450 V/mm at 0.20 mm | Insulating interface, power supply, transformer, inductor, PTC heater, thermostat |
| HN200 | 2.05 W/m·K | 2450 V/mm at 0.20 mm | LED driver, power adapter, general heat sink mounting |
| HN300 | 2.95 W/m·K | 1850 V/mm range | Clamped power module with higher heat flux |
| HN400 | 4.05 W/m·K | 1100 V/mm at 0.20 mm | EV charger and SiC module interface, low BLT, high conductivity priority |
| HN500 and HN600 | 5.0 to 6.0 W/m·K | Metal-filled, non-insulating duty | CPU, GPU and server cooling where conductivity outranks insulation |
Rule of thumb for the design team: if the interface must hold voltage, start at HN100 or HN200 and accept lower conductivity. If the interface is clamped, flat and only needs heat moved, go up the range to HN300 or HN400.
Application instructions| Step | Action |
|---|---|
| 1. Surface preparation | Clean both surfaces with a solvent to remove grease, dust and oxidation, then dry completely before application. |
| 2. Application | Apply by brush, roller, automatic dispenser or screen printing, keeping the deposit inside the heat sink footprint. |
| 3. Spreading | Spread evenly with a clean blade or spatula to the target thickness. A thinner film transfers heat better. |
| 4. Thickness control | Remove excess at the edges with a lint-free cloth. Too much paste lowers efficiency instead of raising it. |
| 5. Assembly | Assemble immediately and torque fasteners to specification to set a stable bond line thickness. |
No, and it should not be asked to. HN100 dielectric strength is 2450 V/mm measured at 0.20 mm, which corresponds to roughly 490 V across a 0.20 mm film as a linear reference. A primary to secondary HIPOT test at 1.5 kV AC or a 400 V DC bus application needs the isolation to come from the housing wall, insulating tape, slot liner or a proper potting layer. HN100 keeps the thermal interface insulating, non-corrosive and clean so the barrier you designed is not bridged by the thermal path.
Why is the 200 °C for 8 days and 280 °C for 3 hours data important for PTC heaters and thermostats?Because those parts run hot continuously and the usual failure mode is drying, not conductivity loss. HN100 shows no powdering after 8 days of continuous 200 °C baking on a 0.2 mm film and no drying after 3 hours at 280 °C on a heating platform. In practice that means the interface stays soft, the thermostat responds at the same temperature cycle after cycle, and the paste does not turn into a hard crust that has to be chipped off during service.
How do we choose between HN100, HN200, HN300 and HN400?Choose by the two constraints that never change: voltage across the interface and heat flux. If the interface must hold voltage, stay at 1.0 W/mK HN100 or 2.05 W/mK HN200 because both carry 2450 V/mm dielectric strength. If the interface is clamped and flat and only heat has to move, go to 2.95 W/mK HN300 or 4.05 W/mK HN400, accepting lower dielectric strength of 1100 V/mm at the 4.0 W/mK grade. Metal-filled 5.0 to 6.0 W/mK grades are for CPU and GPU duty where insulation is not required.
What are the MOQ, packaging, lead time and shipping classification for Southeast Asia?MOQ is 1 kg. Standard packaging is 1 kg and 5 kg plastic drums and custom pack sizes are available. Capacity is 50 tons per month with a typical lead time of 7 to 15 days, batch certificates of analysis on request, technical data sheet and safety data sheet with every shipment, and the product is classified as non-dangerous goods, so sea and air freight to Vietnam, Thailand, Indonesia, Malaysia and the Philippines is routine.
Which parameters belong on the incoming inspection sheet for HN100?Thermal conductivity 1.0 ± 0.1 W/mK by ASTM D5470, specific gravity 1.85 ± 0.08 g/cm3, oil separation 0.3 percent maximum and volatile matter 0.6 percent maximum at 200 °C for 24 hours, penetration 370 ± 20 at 25 °C, breakdown voltage 2450 V/mm at 0.20 mm, operating range −50 to +200 °C, and RoHS 2.0 declaration. Compare each lot certificate of analysis against the sample you approved at design validation.
About this supplierShenzhen Hanast New Materials Co., Ltd. is a China-based source factory for RTV-2 liquid silicone, potting compounds and thermal interface materials. Established in 2010 with a 40,000 m² production base, the company is an export-driven manufacturer with 70 to 80 percent of its business overseas, supplying B2B clients with OEM and ODM encapsulation and thermal management solutions.
Our range covers thermal grease from 1.0 to 6.0 W/m·K, thermally conductive potting compounds, silicone gels, mould making rubber and food grade silicone. Because the thermal grease and the potting compound for the same assembly come from one factory, your engineering team works with one technical contact and your purchasing team consolidates one supplier, one documentation set and one shipment schedule.
![]()
Send your power supply drawing or heat sink specification and our application engineers will confirm the grade, the film thickness target and the dispensing method, and arrange a 1 kg sample drum for your trial build.
Tell us the working voltage, the interface area and the component temperature, and we will reply with the matching HN selective recommendation and a delivery schedule for Southeast Asia.