HN100 is a single-component, non-curing insulating silicone thermal grease rated 1.0 ± 0.1 W/m·K (ASTM D5470) with dielectric strength of 2450 V/mm at 0.20 mm (IEC 60243), specific gravity 1.85 ± 0.08 g/cm³ and penetration 370 ± 20 (1/10 mm). It holds paste consistency from −50 °C to +200 °C, shows no powdering after 8 days of continuous 200 °C baking and no drying after 3 hours on a 280 °C platform, and is specified as resistant to water, ozone and weathering with near-zero free radical content.
This page is written for equipment that lives outdoors in Southeast Asia: pole mounted telecom cabinets, roadside EV chargers, rooftop solar inverters, coastal industrial control boxes and 5G remote radio units. In that environment the interface fails from humidity cycling, condensation and ozone long before it fails from thermal overload, and the grade has to be selected on water and weathering behaviour plus a realistic maintenance interval, not only on conductivity.
| Failure source | What it does to an interface | HN100 position |
|---|---|---|
| Daily condensation cycling | Water film on the heat sink, then evaporation, then repeat. Emulsified grease or oil wash-out leaves a dry patch. | Specified as water resistant with oil separation of 0.3 percent or less, so the paste stays in place and does not wash out of the interface under normal enclosure conditions. |
| Ozone and air pollution | Oxidation of the oil phase, hardening and cracking over years of service. | Near-zero free radical content and ozone and weathering resistance are called out in the TDS, which is the property that keeps the paste soft rather than crusted. |
| Salt laden coastal air | Corrosion of the metal surfaces under the grease and at the edges. | The paste is non-corrosive to the surfaces it touches, but salt fog endurance is a property of the enclosure, the coating and the sealing, not of a 0.1 mm grease film. Do not treat the grease as a corrosion barrier. |
| Solar load and internal heat | Cabinet internal temperature well above ambient, driving volatility loss. | Volatile matter of 0.6 percent or less at 200 °C for 24 hours and no drying after 3 hours at 280 °C, so the oil phase is retained far above realistic cabinet temperatures. |
Outdoor equipment is often specified with a five to ten year service life and a maintenance visit that costs more than the material. What matters for planning is not a marketing lifetime figure, but the three mechanisms that actually age the interface.
| Ageing mechanism | What to inspect at the maintenance visit | Action |
|---|---|---|
| Oil separation and slow bleed | Oil film around the heat sink edge, dry looking paste at the centre of the interface | Wipe and re-apply. A non-curing paste can be refreshed without replacing the module. |
| Volatility loss at the hot spot | Paste that has become stiffer, or a visible dry ring around the hottest device | Re-apply with the same grade and record the measured film thickness before and after. |
| Mechanical movement and pump-out | Paste pushed to one edge, or a bubble path at the clamp line | Re-torque to specification after re-application, and check that the heat sink face is still flat. |
Because the material never cures, there is no hardened crust to chip off and no adhesive bond to break during service. That is the practical reason this grade is used on equipment that has to be serviceable in the field: a technician with a lint-free cloth and a 1 kg drum can restore the interface at the site, without a cure oven and without a new module.
Combining grease with potting for full outdoor protection| Location in the enclosure | Function | Material |
|---|---|---|
| Power device to heat sink, or module to cold plate | Thermal transfer across a clamped interface | HN100 insulating thermal grease |
| Inside the housing around the PCB | Moisture, condensation and contamination protection | Thermally conductive potting compound from the same factory |
| Cable entry and lid | Ingress protection | Gasket and gland, specified by the enclosure supplier |
One supplier for both materials means one technical contact for the thermal and encapsulation design, one documentation set for the audit file and one shipment schedule for the build. It also means the two materials are checked against each other, which matters when a potting compound has to cure in contact with a grease film.
Technical data (TDS HANAST-TDS-018 Rev.1)| Property | Test method / condition | Unit | Value |
|---|---|---|---|
| Appearance | Visual inspection | – | White or grey paste |
| Thermal conductivity | ASTM D5470 | W/m·K | 1.0 ± 0.1 |
| Specific gravity | GB/T 13354-1992 / 25 °C | g/cm³ | 1.85 ± 0.08 |
| Oil separation (oil bleed) | SH/T 0324-1992 / 200 °C, 24 h | % | ≤ 0.3 |
| Volatile matter | SH/T 0337-92 / 200 °C, 24 h | % | ≤ 0.6 |
| Penetration (cone penetration) | GB/T 269-2023 / 25 °C | 1/10 mm | 370 ± 20 |
| High temperature stability | 200 °C constant temperature oven, 0.2 mm film | – | No powdering after 8 days continuous baking |
| Temperature resistance | Heating platform 280 °C, 0.2 mm film | – | No drying after 3 hours continuous baking |
| Breakdown voltage | IEC 60243 / 0.20 mm thickness | V/mm | 2450 |
| Operating temperature range | – | °C | −50 to +200 |
| Environmental resistance | – | – | Water, ozone and weathering resistant, near-zero free radical content |
| Compliance | RoHS 2.0, non-toxic, odourless, non-corrosive | – | Compliant |
Values are measured under standard conditions and are for reference only. For outdoor equipment, validate on the assembled enclosure with your own damp heat and thermal cycling schedule, because the interface in a sealed cabinet behaves differently from a bare sample under test.
Applications: 27 outdoor and humidity exposed interface pointsTelecom and outdoor network equipmentFor the factory owner and plant manager
One grade serves the outdoor cabinet line, the solar inverter line and the service van, so the field technician carries one drum instead of several pad part numbers. Because the paste never cures, a unit returned from the field can be cleaned and re-assembled rather than scrapped, and no oven or cure station is needed in the plant.
For the purchasing and procurement team
MOQ is 1 kg, standard packs are 1 kg and 5 kg plastic drums with custom sizes on request, capacity is 50 tons per month and lead time is typically 7 to 15 days. Every shipment includes TDS and SDS, batch COAs are available on request, and transport is non-dangerous goods to Vietnam, Thailand, Indonesia, Malaysia and the Philippines. Note the storage requirement below 27 °C: plan warehouse space accordingly, because a 35 °C warehouse shortens shelf life even though the product itself is stable at 200 °C in service.
For the electrical and process engineer
Clean and dry the surfaces, keep paste out of any dimension a safety standard measures as creepage or clearance, and clamp immediately to the specified torque so the film is set by hardware. For outdoor units, record the film thickness target in the assembly drawing and inspect the interface after the damp heat and thermal cycling qualification, not only at first article.
For the quality and reliability engineer
Put oil separation, volatile matter, specific gravity and penetration on the incoming inspection sheet, and add breakdown voltage for new batches. For the finished enclosure, run damp heat and thermal cycling on the assembled unit and inspect for dry patches, edge migration and corrosion under the grease film. Report findings against the disassembly photos so the next maintenance interval is planned from data rather than from calendar guesswork.
For the project and product manager
The HN family allows a product line to span insulating and high conductivity duty without changing supplier: 1.0 W/mK HN100 for outdoor and insulating interfaces, 2.05 W/mK HN200 for general electronics, 2.95 W/mK HN300 for clamped modules, 4.05 W/mK HN400 for charger and SiC interfaces, and metal-filled 5.05 W/mK HN500 for server and GPU duty. One technical contact, one document set and one formulation from sample to mass production keeps the qualification effort low.
| Grade | Conductivity | Dielectric strength | Temperature range | Best fit |
|---|---|---|---|---|
| HN100 | 1.0 W/m·K | 2450 V/mm | −50 to +200 °C | Outdoor cabinets, transformer, PTC heater, insulating interfaces |
| HN200 | 2.05 W/m·K | 2450 V/mm | −50 to +200 °C | LED driver, adapter, general heat sink |
| HN300 | 2.95 W/m·K | 1850 V/mm | −40 to +180 °C | Clamped power module, cold plate |
| HN400 | 4.05 W/m·K | 1100 V/mm | −50 to +200 °C | EV charger and SiC module, high heat flux |
| HN500 | 5.05 W/m·K | 1100 V/mm | −40 to +200 °C | AI server, GPU, OBC, PV inverter, PLC |
| Step | Action |
|---|---|
| 1. Surface preparation | Clean both surfaces with a solvent to remove grease, dust and oxidation, then dry completely. On field service, remove all old paste before applying new. |
| 2. Application | Apply by brush, roller, automatic dispenser or screen printing, keeping the deposit inside the contact land area. |
| 3. Spreading | Spread evenly to the target film thickness. A thin film transfers heat better than a thick one. |
| 4. Thickness control | Remove excess at the edges with a lint-free cloth so paste does not enter creepage paths or attract dust. |
| 5. Assembly | Assemble and clamp immediately, torque to specification, then close the enclosure and confirm the gasket and glands are seated. |
No, and it should not be asked to. HN100 is specified as water, ozone and weathering resistant, which means the paste itself does not wash out or harden in a humid enclosure. Ingress protection and condensation control come from the gasket, the breather valve or membrane, the coating and, where a sealed module is needed, the potting compound around the PCB. The correct architecture is grease at the heat sink interface and potting or a sealed housing for the electronics.
How often does the interface need to be re-applied in a tropical outdoor installation?Plan the interval from inspection, not from a fixed number. The indicators are an oil film around the heat sink edge, a dry looking centre at the hottest device, paste pushed to one edge, or a loosened clamp. Because the paste does not cure, any of these can be corrected on site with a wipe and re-apply. Set the first inspection at the same visit as the enclosure gasket check and adjust the interval using the findings from your own damp heat and thermal cycling test.
Is the grease a corrosion barrier for coastal and salt fog environments?No. HN100 is non-corrosive to the surfaces it contacts, but a 0.1 mm grease film is not a salt spray barrier. Coastal durability is decided by the housing material, the coating system, the sealing and the connector plating. Use the grease to keep the thermal interface stable, and specify the enclosure and coating for the salt fog class your customer requires.
What are the MOQ, packaging, lead time and shipping classification for Southeast Asia?MOQ is 1 kg, standard packs are 1 kg and 5 kg plastic drums with custom sizes on request, capacity is 50 tons per month and lead time is typically 7 to 15 days. TDS and SDS ship with every order, batch COAs are available on request, and the product is classified as non-dangerous goods, so sea and air freight to Vietnam, Thailand, Indonesia, Malaysia and the Philippines needs no dangerous goods handling.
Why is the storage requirement below 27 °C when the product works up to 200 °C?Service temperature and storage stability are different questions. In service the paste sits in a thin film on a hot component and the fillers and oil phase are formulated for that duty. In the drum, a large mass of paste held at 35 to 40 °C for months accelerates oil separation and can make the material harder to stir and dispense. Store below 27 °C, keep the drum sealed, and stir before use if separation occurs; performance is not affected by a small amount of separated oil.
About this supplierShenzhen Hanast New Materials Co., Ltd. is a China-based source factory for RTV-2 liquid silicone, potting compounds and thermal interface materials. Established in 2010 with a 40,000 m² production base, the company is an export-driven manufacturer with 70 to 80 percent of its business overseas, supplying B2B clients with OEM and ODM encapsulation and thermal management solutions.
Our range covers thermal grease from 1.0 to 6.0 W/m·K, thermally conductive potting compounds, silicone gels, mould making rubber and food grade silicone. Because the thermal grease and the potting compound for the same outdoor enclosure come from one factory, your engineering team works with one technical contact and your purchasing team consolidates one supplier, one documentation set and one shipment schedule.
Send your enclosure drawing, ingress protection requirement and site climate and our application engineers will confirm the grade, the film thickness target and whether a potting compound is needed inside the housing, and arrange a 1 kg sample drum.
Tell us the outdoor temperature range, the humidity profile and the maintenance interval you must support, and we will reply with the interface recommendation and a delivery schedule for Southeast Asia.